Shift Brief
Demo North Pumping Station · frozen as of 2026-10-12 · condition index is an explainable demonstration index, not a probability of failure.
Key findings
- P-102Wire-to-water efficiency 0.7121 → 0.5674 (20.32% deterioration). Cause unverified. Evidence →
- V-201Last stroke test: failed. Operability finding requires engineering review. Evidence →
- P-104INSUFFICIENT EVIDENCE — no valid run data. Not healthy, not low risk: test required. Evidence →
- P-103Recent median vibration 6.44 mm/s (watch ≥ 4.5). Bearing fault not confirmed. Evidence →
Next best inspection
A-11 · Test standby pump
P-104 · uncertainty 0.9 · information value 40 pts
₹11,000 · 3 crew h · no outage
Record a findingAll assets (8)
P-101
Pump Train 1
Pump train · criticality 4/5
Confidence 0.95
No configured high-severity deterioration threshold crossed
P-102
Pump Train 2
Pump train · criticality 5/5
Confidence 0.95
Inspection overdue 22 d
Wire-to-water efficiency decreased 20.3% versus first-week asset baseline
P-103
Pump Train 3
Pump train · criticality 4/5
Confidence 0.95
Recent median vibration exceeds synthetic watch threshold
P-104
Pump Train 4
Pump train · criticality 5/5
Confidence 0.10
Inspection overdue 43 d
No valid recent operating telemetry; do not infer that standby equipment is healthy or failing
V-201
Discharge Isolation Valve A
Isolation valve · criticality 5/5
Confidence 0.90
Inspection overdue 41 d
Last documented stroke test failed; treat as an operability finding requiring engineering review
V-202
Discharge Isolation Valve B
Isolation valve · criticality 3/5
Confidence 0.62
Inspection overdue 22 d
Last known stroke test passed, but current operability must be revalidated if overdue
VFD-301
Variable Frequency Drive 1
Variable frequency drive · criticality 4/5
Confidence 0.85
Recent cabinet-temperature median exceeds illustrative watch threshold
MCC-401
Motor Control Centre A
Motor control centre · criticality 4/5
Confidence 0.85
No configured temperature threshold crossed