JalaRakshak AIby quaStrat

P-102 · Pump Train 2

Pump train · duty · criticality 5/5 · commissioned 2014 · source GIS-P-102

Condition index vs confidence

Index 58.0

Condition index (0–100)

58

Evidence confidence

0.95

Index is an explainable demonstration score, not a probability of failure.

Plain-English explanation

Median wire-to-water efficiency fell from 0.7121 (first week, 7 valid days) to 0.5674 (last week, 7 valid days), a 20.32% deterioration. Recent median vibration is 4.07 mm/s and bearing temperature 77.75 °C. The cause is not established by these data.

  • Wire-to-water efficiency decreased 20.3% versus first-week asset baseline
  • Recent median bearing temperature exceeds synthetic watch threshold
  • Repeat low-flow work-order history
  • Inspection overdue by 22 days; this affects inspection priority, not proof of physical failure
baseline wire to water efficiency: 0.7121recent wire to water efficiency: 0.5674efficiency drop pct: 20.32recent median vibration mm s: 4.07recent median bearing temp c: 77.75valid baseline days: 7valid recent days: 7

Wire-to-water efficiency (valid days)

Vibration mm/s

Bearing temperature °C

Raw readings (28)

Swipe sideways to see all columns.

Baseline window: before 2026-09-21. Recent window: from 2026-10-05. Source: SYNTHETIC historian daily summary.

DateFlow m³/hSuct. barDisch. barΔP barkW inHydr. kWEff.Vib.Brg °CStatus
2026-09-14216.001.035.544.50737.9027.040.71352.4569.00valid
2026-09-15217.241.035.534.50438.0227.180.71492.5069.43valid
2026-09-16217.951.035.534.49538.0927.210.71452.5369.68valid
2026-09-17217.811.035.514.48238.0827.120.71212.5269.63valid
2026-09-18216.891.035.504.46937.9926.920.70872.4969.31valid
2026-09-19215.591.035.494.45837.8626.700.70522.4368.86valid
2026-09-20214.461.035.484.45337.7526.530.70272.3968.46valid
2026-09-21214.001.035.494.45537.7026.480.70252.3768.30valid
2026-09-22214.401.035.494.46237.7426.570.70412.3968.44valid
2026-09-23215.501.035.504.47437.8526.780.70762.4368.82valid
2026-09-24215.511.035.514.47638.2226.800.70112.5969.88valid
2026-09-25215.171.035.504.47538.5626.750.69362.7470.82valid
2026-09-26214.071.035.504.47038.8226.580.68472.8671.49valid
2026-09-27212.111.035.494.45838.9926.270.67372.9471.86valid
2026-09-28209.591.035.474.44039.1125.850.66093.0072.03valid
2026-09-29207.031.035.454.41739.2225.400.64773.0672.19valid
2026-09-30204.981.035.424.39239.3925.010.63493.1472.53valid
2026-10-01203.751.035.404.36839.6424.720.62373.2673.15valid
2026-10-02203.331.035.384.34739.9624.550.61443.4074.06valid
2026-10-03203.331.035.364.33340.3324.470.60683.5675.11valid
2026-10-04203.181.035.364.32540.6924.410.59993.7276.12valid
2026-10-05202.401.035.354.32340.9824.300.59313.8576.90valid
2026-10-06200.751.035.354.32441.1824.110.58553.9577.38valid
2026-10-07198.391.035.364.32541.3223.830.57684.0177.61valid
2026-10-08195.771.035.354.32341.4323.510.56744.0777.75valid
2026-10-09193.471.035.344.31541.5723.190.55784.1478.00valid
2026-10-10191.921.035.334.30141.7822.930.54884.2478.51valid
2026-10-11191.221.035.314.28042.0822.730.54034.3779.32valid

Inspection evidence

No inspection records.

Maintenance history

  • WO-0002 · 2026-08-22
    reactive low flow: closed — Low-flow event; root cause not confirmed
  • WO-0003 · 2026-09-08
    reactive low flow: closed — Repeat reduced output; follow-up suggested

Engineer review