JalaRakshak AIby quaStrat

P-101 · Pump Train 1

Pump train · duty · criticality 4/5 · commissioned 2017 · source GIS-P-101

Condition index vs confidence

Index 12.1

Condition index (0–100)

12.1

Evidence confidence

0.95

Index is an explainable demonstration score, not a probability of failure.

Plain-English explanation

Median wire-to-water efficiency fell from 0.7196 (first week, 7 valid days) to 0.7095 (last week, 7 valid days), a 1.4% deterioration. Recent median vibration is 2.28 mm/s and bearing temperature 67.75 °C. The cause is not established by these data.

  • No configured high-severity deterioration threshold crossed
baseline wire to water efficiency: 0.7196recent wire to water efficiency: 0.7095efficiency drop pct: 1.4recent median vibration mm s: 2.28recent median bearing temp c: 67.75valid baseline days: 7valid recent days: 7

Wire-to-water efficiency (valid days)

Vibration mm/s

Bearing temperature °C

Raw readings (28)

Swipe sideways to see all columns.

Baseline window: before 2026-09-21. Recent window: from 2026-10-05. Source: SYNTHETIC historian daily summary.

DateFlow m³/hSuct. barDisch. barΔP barkW inHydr. kWEff.Vib.Brg °CStatus
2026-09-14219.001.105.664.55538.5027.710.71972.2068.00valid
2026-09-15220.371.105.654.55238.7327.860.71952.2668.43valid
2026-09-16221.141.105.644.54438.7927.910.71962.3068.68valid
2026-09-17220.991.105.634.53338.6327.830.72032.2968.63valid
2026-09-18219.981.105.624.51938.3727.610.71972.2468.31valid
2026-09-19218.541.105.614.50538.2127.350.71572.2267.86valid
2026-09-20217.311.105.594.49438.2727.130.70882.2867.46valid
2026-09-21216.801.105.594.48738.5127.020.70172.3067.30valid
2026-09-22217.251.105.584.48538.7427.070.69872.2867.44valid
2026-09-23218.451.105.594.48938.7927.240.70222.2367.82valid
2026-09-24219.891.105.604.49738.6227.470.71122.2468.28valid
2026-09-25220.951.105.614.50938.3627.670.72142.2968.62valid
2026-09-26221.161.105.624.52338.2127.790.72722.3068.69valid
2026-09-27220.441.105.644.53638.2727.780.72582.2768.46valid
2026-09-28219.101.105.654.54738.5127.670.71862.2068.03valid
2026-09-29217.711.105.654.55438.7427.540.71092.2667.59valid
2026-09-30216.881.105.664.55538.7927.440.70742.3067.33valid
2026-10-01216.971.105.654.55038.6227.420.71012.2967.35valid
2026-10-02217.931.105.644.54138.3627.490.71662.2567.66valid
2026-10-03219.361.105.634.52938.2027.600.72242.2268.11valid
2026-10-04220.631.105.624.51538.2727.670.72302.2768.52valid
2026-10-05221.201.105.604.50238.5227.660.71812.3068.70valid
2026-10-06220.811.105.594.49238.7427.550.71122.2868.58valid
2026-10-07219.651.105.594.48638.7927.370.70562.2368.21valid
2026-10-08218.201.105.594.48638.6127.190.70422.2467.75valid
2026-10-09217.101.105.594.49138.3527.080.70622.2967.40valid
2026-10-10216.821.105.604.50038.2027.100.70952.3067.31valid
2026-10-11217.491.105.614.51338.2827.260.71222.2767.52valid

Inspection evidence

  • INSP-005 · 2026-10-03
    walkdown: passed (normal) — No anomaly found verified

Maintenance history

  • WO-0001 · 2026-09-30
    preventive service: completed — Routine seals and alignment check; no fault

Engineer review